BLOG

Specializing in the research, development, production, sales, equipment consulting, maintenance, and accessory services of heat exchange technology, equipment, and systems

25

2018

-

06

Installation, Use, and Maintenance of Plate Heat Exchangers

Author:


Summary:

1. The heat exchanger must be installed vertically, and the low position of all lower connecting pipes should have a discharge port and valve installed; insulation should be applied as much as possible according to needs; leave space for maintenance. 2. When starting up, ensure that the outlet valves on both sides are open, first slowly open the cold side fluid valve to allow the cold fluid to circulate, then slowly open the hot fluid valve, and try to avoid large pressure fluctuations during operation. When shutting down, first close the hot fluid inlet valve and then the cold fluid inlet valve, also operating slowly. 3. When stopping, ensure that the residual liquid in the channels on both sides is completely discharged (open the discharge port at the bottom of the pipe) and check whether the inlet valve is tightly closed.


  1. The heat exchanger must be installed vertically, and the low position of all lower connecting pipes should have a discharge port and valve installed; insulation should be applied as much as possible according to needs; leave space for maintenance.
 
  2. When starting up, ensure that the outlet valves on both sides are open. First, slowly open the cold side fluid valve to allow the cold fluid to circulate, then slowly open the hot fluid valve. During operation, try to avoid large pressure fluctuations. When shutting down, first close the hot fluid inlet valve and then the cold fluid inlet valve, also operating slowly.
 
  3. When stopping, ensure that the residual liquid in the discharge channels on both sides is cleaned (open the discharge port at the bottom of the pipe) and check if the inlet valve is tightly closed.
 
  4. When using steam single-channel disinfection, ensure that the liquid on the other side of the channel is completely discharged, with no residue, and the steam valve must be opened slowly.
 
  5. Before disassembly, measure the distance between the two frame clamps and record the clamping size; when disassembling, stand directly behind the column and use both hands to remove and hang the plates, avoiding uneven force and tilting that could cause deformation. Loosen and tighten the screws diagonally and evenly, ensuring the clamping size is appropriate and not overly tight; mark the special position plates and rubber strips to avoid being unable to reassemble them in the original state; when cleaning the plates, the sealing rubber strips should be removed for individual cleaning, and do not use iron brushes or soak in corrosive liquids; when hanging the rubber strips back on the plates, ensure they do not shift (a small amount of glue can be used for fixing, but not too much or it should not run outside the rubber pad).
 
  6. For other operational matters, please refer to the "User Manual."

Heat Exchanger Standards

Heat Exchanger Standards

2025-09-17


Heat exchange equipment solutions

Chongqing Southwest Saiwei Heat Exchange Equipment Co., Ltd. is committed to providing customers with excellent heat exchange equipment solutions. With the rapid development of the industrial field, the demand and application of heat exchange equipment are becoming more and more extensive. The company deeply knows that each customer's needs are unique, so customized solutions have become our core competitiveness.

2025-08-13


Which heat exchanger is good?

Which heat exchanger is good?

2025-07-22


Heat exchanger material and corrosion resistance

Heat exchanger material and corrosion resistance

2025-07-08


Which heat exchanger is good?

Which heat exchanger is good?

2025-06-27


Chongqing Southwest Saiwei Heat Exchange Equipment Co., Ltd. boosts the take-off of China's heat exchange technology.

Chongqing Southwest Saiwei Heat Exchange Equipment Co., Ltd. boosts the take-off of China's heat exchange technology.

2025-05-30